240 CFM Centrifugal Blower

240 CFM Centrifugal Blower

MOQ : 1 Piece

Business Type Manufacturer, Exporter, Supplier
Automatic Grade Automatic
Power 1-3kw
Driven Type Electric
Click to view more

Preferred Buyer From

Location Worldwide

Product Details

Warranty
1year
Codition
New
Presssure
High Pressure, Low Pressure, Medium Pressure
  • Impeller Φ 120 × 55 mm
  • Continuous Rating.
  • Aluminium Impeller MS Casing.
  • Integral Induction Motor in Aluminium Body.
  • Air Flow Vs Static Pressure
  • Centrifugal Blowers move air by means of the centrifugal force generated by rotating cylindrical impeller.
  • Used for applications where increased air pressure, increased static pressure, high airflow is required.
  • Centrifugal blowers have a small outlet, which concentrates air in a single direction, and are therefore suitable for local cooling.
Read More...

Yes! I am interested


Specifications

Model Supply Voltage Frequency
Hz
Current
A
Speed
RPM
Max Air Flow
CFM
Max Static Pressure Capacitor μF
Pa mm of H2O
CB 1255 W Single Phase 110V 60 0.9 2600 240 300 30 6
CB 1255 X Single Phase 230V 50 0.4 2600 240 285 29 1.85
CB 1255 Y Three Phase 230V 60 0.5 2600 240 300 30 -
CB 1255 Y Three Phase 415V 50 0.2 2600 240 285 29 -

Air Flow Vs Static Pressure

Air Flow Vs Static Pressure
  • Centrifugal Blowers move air by means of the centrifugal force generated by rotating cylindrical impeller.
  • Used for applications where increased air pressure, increased static pressure, high airflow is required.
  • Centrifugal blowers have a small outlet, which concentrates air in a single direction, and are therefore suitable for local cooling.

Dimensions

Dimensions

Wiring Diagram

Wiring Diagram

Wiring Diagram for Single Phase Blower
Ensure that impeller is rotating in counter clockwise direction. Airflow is maximum.

 

Short Black wires & connect the capacitor as shown. To change the direction, connect the supply wire from White to Red.


Wiring Diagram

Wiring Diagram

Red wires are for running winding & Black wires are for starting winding. To Change the direction, interchange Black wire or Red wire.


Wiring Diagram for Three Phase Blower

Wiring Diagram for Three Phase Blower

To Change the direction, interchange any two wires between U, V & W. For 415 V supply, wires are connected in Star configuration. Short White, Black & Blue wire & then insulate properly


Wiring Diagram for Three Phase Blower

Wiring Diagram for Three Phase Blower

To change the direction, interchange any two wires between U, V & W. For 230 V 3 Ph supply, wires are connected in Delta Configuration.